Benzene / Btex Analyzer

                  Benzene / Btex Analyzer

 Monitoring of benzene, toluene, ethylbenzene, xylenes (BTEX) and other hydrocarbons in ambient air.The Vair-9013 Series BTEX analyser is built for the  measurement of benzene, toluene and xylene isomers in ambient

           Hydrocarbon Selection

Benzene is a carcinogenic compound and it is harmful already in very low concentrations; there is no absolute safe concentration limit for benzene.By CPCB   regulations, measurement of benzene in ambient air is obligatory. The yearly mean value must be below 5µg/m3. The concentration of benzene inambient air varies from under 0.1 to above 100 micrograms per m3.

   Benzene in ambient air is coming from evaporated fuel, either from gas filling stations or from cars. Furthermore, it is emitted by cars by burning fuel andfrom other    burning processes like bio fuel heating or forest fires.Toluene, Ethylbenzene and o-, m-, p-Xylene are standards that are included in the analyser configuration. This group

                 Measuring Principle

  The Vair-9013 Series BTEX analyser can measure up to 40 components.With different settings and suitable calibration gas it is possible to measure components like  octane, chloroethenes, trimethylbenzenes in one 30-minute run. Data processing and communication are prepared for this.The customer can also specify a list of  components that have to be measured and Vasthi can include those compounds in the settings of the system. The customer needs to buy the suitable calibration gas to check this and calibrate the system.

                Hydrocarbon Selection

   Benzene / Btex Analyzer  instrument is a gas chromatograph with a built-in pre-concentration system. Hydrocarbons are pre-concentrated on Tenax GR, desorbed thermally, and separated in an appropriate column to reach optimal separation from interfering hydrocarbons.

 .Alternative columns are available for special applications. Analysis is done by a photo ionization detector (PID). This ensures highly specific sensitivity for benzene and  aromatic hydrocarbons in general.A standard industrial PC, running under Windows, is used. The user-friendly software stores all the chromatograms on the hard disk and data can be interpreted easily with this intuitive software. Data can also be transferred by network and modem connection. Besides this, analogue and digital output options are available to communicate with other data logging systems using several data protocols.

  Simple operation, good reliability and low maintenance costs are important to us. With a worldwide network of trained distributors the end-user can be sure that the  analyser comes with an individualized training and that local support is available when needed. Vair-9013 consumes a small quantity of nitrogen as carrier gas.

 Preventive maintenance is only required once a year. For good data quality it is recommended to have a regular (automatic) calibration or validation. In the software an automatic multipoint validation/calibration is possible using calibration gas of one concentration per component by using different volumes of air passing over the pre-concentration trap. The expected lifetime of the analyser is 10 years. Consumable parts are economically priced.





 

FEATURES :

Technical Description PID detector. Lowest detection level for benzene 0.1 µg/m3 (0.03 ppbV). Range: standard 0-20 ppbV, with software adaptations up to 300 ppbV possible
Standard Calibration Standard 4 point calibration provided for BTX in range 4 to 16 ppbV
Extra Compounds Available The software of the analyser is prepared to measure up to 40 hydrocarbons. Ask which hydrocarbons you want to add and we will check if this is possible with the existing hardware. Ask Synspec for advise about calibration gas and peak window setting.
Reproducibility Typical <3% at 1 ppbV (benzene, with capillary column)
Gas Consumption Nitrogen: quality 5.0, 4 bar, 6 ml / min
Dimensions 19” rack, 5 standard Height Units, depth 43 cm (W 48,3 D 43 H 22 CM), WEIGHT 19 kg
Hardware Internal industrial x86 based computer, suitable for measuring and saving data up to 10 years. Hard disk, full color touchscreen, various data connection options.
Communication Direct control via touchscreen, keyboard or mouse. External data communication via RS232, analog and digital outputs via TCP-IP.
Standard available protocols ASCII terminal, Hessen, Gesytec and MODBUS; other protocols on demand.
Included Software Windows embedded and GC955 software. Direct control via touchscreen, keyboard or mouse via remote host (RS232/modem) or Ethernet. Software for running the analyser and demo version for data evaluation and reprocessing on desktop is included.
Power Demand 230 V AC, 100 VA (115 V AC available) 50/60 Hz
What is the BTEX Analyzer?

The BTEX Analyzer is an online gas monitoring system designed to continuously measure Benzene, Toluene, Ethylbenzene, and Xylene (BTEX) in ambient or industrial air.

Why is BTEX monitoring important?

BTEX compounds are volatile organic compounds (VOCs) with significant health and environmental impacts — monitoring helps ensure air quality compliance and safety.

How does this analyzer detect BTEX compounds?

It uses advanced detection technology (such as gas sensors or chromatographic modules) for precise and continuous quantification of BTEX concentrations.

Where is the BTEX Analyzer used?

This analyzer is ideal for environmental monitoring stations, industrial emission monitoring, petrochemical facilities, and research labs.

Does it support remote data output?

Yes — it supports remote connectivity and data export to SCADA systems, servers, or cloud platforms for real-time tracking and alerts.

Related Products

ClimaGuard

VE Clima Guard Monitor up to 16gaspol lutant and particles simultaneously an get continuous and real-time d

PM 10 and PM 2.5 (CAAQMS)

The V-air 9009 CAAQMS uses Beta Attenuation Monitoring technology

Ambient SO2 Gas Analyzer (CAAQMS)

An Ambient SO2 Gas Analyzer is a device designed to measure the concentration

Ambient NOx Gas Analyzer (CAAQMS)

An Ambient NOx Gas Analyzer is an instrument designed to measure

Ambient Ozone Gas Analyzer (CAAQMS)

An ambient ozone gas analyzer is a device designed to measure the concentration

Ambient CO Gas Analyzer (CAAQMS)

An Ambient Carbon Monoxide (CO) Gas Analyzer is a device designed to measure

Million Plus Cities Urban Air Quality Monitor (CAAQMS)

Million-plus cities urban air quality monitor (MCQ) monitoring station is a new type

Multi point calibrator

Multi-point calibrator can be employed to accurately calibrate a variety

Vair 3000 Series

V-air 3000 Series online dust monitor with laser scattering method for PM 10, PM 2.5

Ultrasonic Weather Monitoring Station

An Ultrasonic Weather Monitoring Station is a sophisticated device that utilizes

Zero Air Unit

Zero Air Generator" or "Zero Air Unit." In analytical chemistry and environmental

Portable Multi Point Calibrator &Zero Air Unit

Low Volume PM Sampler(PM2.5&PM10)

Particulate matter samplers come in a variety of forms and are intended for a range of uses

Particle Counter

particle counter is a scientific instrument used to measure and count the number of particles in a

Benzene Series Online Analyzer

Our company has developed the Vair-9005 Benzene Series Online Analyzer (Gas Chromatography) by combining the p

HYDROGEN FLUORIDE (HF) GAS ANALYZER

LGT-180 is a 18" panel mounted type tunable HF Gas Analyzer for Industrial Online Analysis and Environmen

Benzene / Btex Analyzer

The Vair-9013 Series BTEX analyser can measure up to 40 components.With different settings and suitable calibr

HYDROGEN (H2) GENERATOR

With advanced features and robust construction, this generator ensures a steady and reliable hydrogen supply w

ONLINE VOC GAS ANALYSER WITH GC- FID TECHNOLOGY

Ambient CO2 Gas Analyzer (CAAQMS)

An Ambient Carbon Monoxide (CO2) Gas Analyzer is a device designed to measure

OUTDOOR MICROPHONES

Carbon Monoxide Analyzer

Kentek CO Analyzer is the analyzer that measures the minimum amount of CO in air correctly through the optica

BPM-200 Continuous Particuate Monitor FPI

Particulate by using well applied beta ray attenuation technology.

Asian.webp
CPCB.webp
BHEL (2).webp
CPGCL (2).webp
CSIR.webp
DRDO (2).webp
Rajendra University.webp
ECIL (2).webp
HPGCL.webp
Hindustan organic.webp
ISRO.webp
INS Jalaswa Logo.webp
Dr.Reddy's (1).webp
JINDAL STEEL.webp
JSW (2).webp
Madras Fertilizers.webp
Meghamani Organics.webp
Minister of Diffence.webp
ONGC.webp
Rastriya chemical Fertilzer.webp
RFCL.webp
Sigareni.webp
RVUN.webp
Tata.webp
West Bengal.webp