ONLINE VOC GAS ANALYSER WITH GC- FID TECHNOLOGY

Industrial air pollution emission standards stipulate explicit limit requirements for the contents of NMHC, benzene, toluene, xylene, chlorobenzene, chlorine, alkanes, and more than 40 volatile organism., and require real time monitoring for the content of non - methane hydrocarbons, benzene and other volatile organic waste gases for applications such as rubber mixing, vulcanization equipment exits of tires and other rubber products enterprises ; cold drum, tar storage and tank area of coking chemical enterprises ; workshops and exhaust area of steel - making and battery industry enterprises. Vasthi - NMHC VOCs online analyzer is a new generation of Vasthi NMHC which assist environmental supervision bureau to carry out effective detection and control on industrial emission.

Vair - 9006 - NMHC VOCs online analyzer is a high temperature version of Vair - 9006 - NMHC. There is specialized heating box inside for analytic gas path. By adopting air bath heating method, it can make chromatographic column and gas paths before of after it in high temperature condition. During detection and sampling of high - temp. VOCs for specific pollutants (such as diesel engine emission of shipping vessel, flue gas emission of petrochemical refinery and etc. ), it offers heat tracing for sampling gas path / analysis gas path which will effectively prevent gas of high boiling point and low steam pressure from attaching to the walls of gas path. It can solve the problem of low detection results of gas sample in specific high temperature condition. Foe exclusive structure design.


                                                              Principle
Vair - 9006 - NHMC VOCs online analyzer is also a VOCs monitoring product which adopts GC-FID analysis method widely recognized in the world. GC technology is a gas separation technology that multi-component gas mixture pass through special chemical fillings of chromatographic column, then effectively separated while flow out of the column. For different boiling point and polarity of different components, the gas component of high coiling point and small polarity difference flows slowly and flows out late ; the gas component of low boiling point and big polarity difference flows faster and flows out earlier. Under the conditions of proper column length, temperature and material, gas mixture will be finally separated individually.

FID technology is one of the effective methods for detecting organic of low concentration. After been separated from the column, the gas continuously delivered into the FID detector by the carrier gas. Under high temperature ionization of FID detector hydrogen flame, the gas molecular bond is opened and releases the free ions and electrons. Under high voltage electric field of FID detector, released electrons move to one electrode of the electric field, and generate signal current from the measurement circuit which is related to the quantity of gas components into the detector. The total signal collected at the certain sampling period illustrates the content if the certain gas components.

                                                Application
Coated Furniture Factory / special Gas Lab / Process Control/Textile Printing and Dyeing Plants/Drinks and Food Industries / Flue Gas Emission Control / Fermentation
Control I Chemicals Production or Treatment Plant/Urban Environmental Gas Monitoring/Auto Industry

                                             

 

                                  

FEATURES :

  • Each time after sampling injection , the analyzer purges sample loop and back blows column automatically, so that the components without detection needs can be rapidly discharged from the system reversely, to shorten the analysis cycle time efficiently.
  • It offers heat tracing for whole process, including sample gas collection, transfer and detection by adopting air bath technique and electrical heating to ensure that sample gas of high boiling point will not loss for condensation and attach to column during process.
  • Use Silco  steel processing gas lines to greatly reduce the adsorption and residual of the sample gas within the tube wall.
  • FID detector has automatic ignition and alarm function after flameout, effective security management and control of the hydrogen flame gas path.
  • Analyzer supports multi-detector configuration, continuously analysis the sample gas simultaneously, improve the ability of complex samples analysis.
  • Support TCP/IP network remote control of the analyzer,  also support directly site operating analyser  by touching the LCD screen.Can be equipped with flameproof enclosure for installation requirements of anti-explosion occasion.
Measurement Principle GC-FID
Measurement Range 0.01ppm-1000ppm (by methane)
Resolution 0.001 ppm
Baseline Noise 5x10-13A
Baseline Drift 55x10-12A (30min)
Detection Limit 55x10-10g/s (by methane)
Qualitative Repeatability RSD 51.0%
Quantitative repeatability RSD 52.0%
Span Drift RSD 53.0%(4th)
Temperature stability of Oven 50.5°C
Measurement Period 2min-30min (there will be increased or decreased in different components)
Air Circuit input/ Output Interface 1/8- Stainless steel cutting screwed nipple
Input flow of sample gas 200 mil min
Air input parameter Air(except hydrocarbon), >99.999%, 0.30±0.01 MPa
Hydrogen input parameter H2, 99.999%, 0.30±0.01MPa
Carrier Gas Input parameter F12, 99.999%, 0.30±0.01MPa
Auxiliary Gas Input Parameter Oil less air compressed air, 0.3MPa-0,6MPa
Display Touch LCD screen
Power supply 230V AC,50Hz-60Hz
Power Consumption 500W (Heating tracer for sampling not included
Weight 26Kg
Size 483mm(w)x258mm(H)x498mm (D)
Sample & Carrier Gas Control Mechanical adjustment, electronic feedback
Communication Input 10/100M Ethernet interface, RS232
Communication Protocol Modbus-RTU

Catalog/Brochure

Catalog streamline the selection process by offering concise visual and descriptive overviews of product.

Download Catalog    

Get A Free Quote

    If You Need Any Help Contact With Us

    +91 7382708685

    Related Products

    PM 10 and PM 2.5 (CAAQMS)

    The V-air 9009 CAAQMS uses Beta Attenuation Monitoring technology

    Ambient SO2 Gas Analyzer (CAAQMS)

    An Ambient SO2 Gas Analyzer is a device designed to measure the concentration

    Ambient NOx Gas Analyzer (CAAQMS)

    An Ambient NOx Gas Analyzer is an instrument designed to measure

    Ambient Ozone Gas Analyzer (CAAQMS)

    An ambient ozone gas analyzer is a device designed to measure the concentration

    Ambient CO Gas Analyzer (CAAQMS)

    An Ambient Carbon Monoxide (CO) Gas Analyzer is a device designed to measure

    Million Plus Cities Urban Air Quality Monitor (CAAQMS)

    Million-plus cities urban air quality monitor (MCQ) monitoring station is a new type

    Multi point calibrator

    Multi-point calibrator can be employed to accurately calibrate a variety

    Vair 3000 Series

    V-air 3000 Series online dust monitor with laser scattering method for PM 10, PM 2.5

    Ultrasonic Weather Monitoring Station

    An Ultrasonic Weather Monitoring Station is a sophisticated device that utilizes

    Zero Air Unit

    Zero Air Generator" or "Zero Air Unit." In analytical chemistry and environmental

    Portable Multi Point Calibrator &Zero Air Unit

    Low Volume PM Sampler(PM2.5&PM10)

    Particulate matter samplers come in a variety of forms and are intended for a range of uses

    Particle Counter

    particle counter is a scientific instrument used to measure and count the number of particles in a

    Benzene Series Online Analyzer

    Our company has developed the Vair-9005 Benzene Series Online Analyzer (Gas Chromatography) by combining the p

    HYDROGEN FLUORIDE (HF) GAS ANALYZER

    LGT-180 is a 18" panel mounted type tunable HF Gas Analyzer for Industrial Online Analysis and Environmen

    Benzene / Btex Analyzer

    The Vair-9013 Series BTEX analyser can measure up to 40 components.With different settings and suitable calibr

    HYDROGEN (H2) GENERATOR

    With advanced features and robust construction, this generator ensures a steady and reliable hydrogen supply w

    ONLINE VOC GAS ANALYSER WITH GC- FID TECHNOLOGY

    APCPL.webp
    APGENCO (2).webp
    Asian.webp
    Aditya Birla (2).webp
    CPCB.webp
    BHEL (2).webp
    CPGCL (2).webp
    CSIR.webp
    DRDO (2).webp
    Rajendra University.webp
    ECIL (2).webp
    HPGCL.webp
    Hindustan organic.webp
    ISRO.webp
    INS Jalaswa Logo.webp
    Dr.Reddy's (1).webp
    JINDAL STEEL.webp
    JSW (2).webp
    Madras Fertilizers.webp
    Meghamani Organics.webp
    Minister of Diffence.webp
    ONGC.webp
    Rastriya chemical Fertilzer.webp
    RFCL.webp
    Sigareni.webp
    RVUN.webp
    Tata.webp
    West Bengal.webp