PM10 and PM2.5 Particulate Matter Monitor (CAAQMS)

The Vair-9009 by Vasthi Instruments is an online, real-time beta attenuation particulate monitor for continuous ambient air quality monitoring (CAAQMS). It measures particulate matter collected on glass fibre filter tape with a one-hour time resolution, using in-line sampling geometry that measures beta attenuation across the filter media while sampling—supporting uninterrupted 24/7 operation with strong sensitivity and temporal resolution.

A unique in-situ sampling technique holds the beta measurement at a near-constant temperature above ambient conditions. This helps prevent loss of semi-volatile particulate and excess moisture in the sample stream, reducing measurement error without costly Nafion dryers, flow splitters, or air-conditioned shelters.

The instrument is housed in a lightweight equipment shelter with an easily removable pump box—ideal where permanent structures or walk-in shelters are not available. No major component exceeds 40 lb (18 kg), so a single technician can carry, install, and commission the system in minutes, with lower power consumption and simpler maintenance.

FEATURES :

The Vair-9009 is engineered for demanding CAAQMS deployments:

  • In-situ PM measurement for high accuracy and minimal measurement artifacts
  • Reduced background determination frequency
  • Reliable performance under high ambient dew-point conditions
  • Remote operation with cloud-ready communications
  • Advanced diagnostics for faster field troubleshooting
  • Improved sensitivity compared with other in-line beta attenuation mass monitors
  • Meteorological and auxiliary sensor inputs
  • Integrated mass calibration system
What is the working principle of the Vair-9009 series?

The Vair-9009 series operates using Beta Attenuation Monitoring (BAM) technology.

What national / US EPA approved technology is used for measuring particulate matter?

Beta Attenuation Monitoring (BAM) is the established method referenced for regulatory particulate measurement programmes.

How long does one measurement take?

A standard cycle provides a one-hour measurement. Sampling duration can be configured for local conditions—for example shorter or longer collection windows depending on ambient pollution levels.

How often does the filter tape need to be changed?

Typically every 45 days when operating at one sample per hour.

Catalog/Brochure

Catalog streamline the selection process by offering concise visual and descriptive overviews of product.

Download Catalog    

Get A Free Quote

    If You Need Any Help Contact With Us

    +91 7382708685

    Related Products

    ClimaGuard

    VE Clima Guard Monitor up to 16gaspol lutant and particles simultaneously an get continuous and real-time d

    PM10 and PM2.5 Particulate Matter Monitor (CAAQMS)

    Vair-9009 continuous ambient particulate monitor using Beta Attenuation Monitoring (BAM) for accurate, real-ti

    Ambient SO2 Gas Analyzer (CAAQMS)

    An Ambient SO2 Gas Analyzer is a device designed to measure the concentration

    Ambient NOx Gas Analyzer (CAAQMS)

    An Ambient NOx Gas Analyzer is an instrument designed to measure

    Ambient Ozone Gas Analyzer (CAAQMS)

    An ambient ozone gas analyzer is a device designed to measure the concentration

    Ambient CO Gas Analyzer (CAAQMS)

    An Ambient Carbon Monoxide (CO) Gas Analyzer is a device designed to measure

    Million Plus Cities Urban Air Quality Monitor (CAAQMS)

    Million-plus cities urban air quality monitor (MCQ) monitoring station is a new type

    Multi point calibrator

    Multi-point calibrator can be employed to accurately calibrate a variety

    Vair 3000 Series

    V-air 3000 Series online dust monitor with laser scattering method for PM 10, PM 2.5

    Ultrasonic Weather Monitoring Station

    An Ultrasonic Weather Monitoring Station is a sophisticated device that utilizes

    Zero Air Unit

    Zero Air Generator" or "Zero Air Unit." In analytical chemistry and environmental

    Portable Multi Point Calibrator &Zero Air Unit

    Low Volume PM Sampler(PM2.5&PM10)

    Particulate matter samplers come in a variety of forms and are intended for a range of uses

    Particle Counter

    particle counter is a scientific instrument used to measure and count the number of particles in a

    Benzene Series Online Analyzer

    Our company has developed the Vair-9005 Benzene Series Online Analyzer (Gas Chromatography) by combining the p

    HYDROGEN FLUORIDE (HF) GAS ANALYZER

    LGT-180 is a 18" panel mounted type tunable HF Gas Analyzer for Industrial Online Analysis and Environmen

    Benzene / Btex Analyzer

    The Vair-9013 Series BTEX analyser can measure up to 40 components.With different settings and suitable calibr

    HYDROGEN (H2) GENERATOR

    With advanced features and robust construction, this generator ensures a steady and reliable hydrogen supply w

    ONLINE VOC GAS ANALYSER WITH GC- FID TECHNOLOGY

    Ambient CO2 Gas Analyzer (CAAQMS)

    An Ambient Carbon Monoxide (CO2) Gas Analyzer is a device designed to measure

    OUTDOOR MICROPHONES

    Carbon Monoxide Analyzer

    Kentek CO Analyzer is the analyzer that measures the minimum amount of CO in air correctly through the optica

    BPM-200 Continuous Particuate Monitor FPI

    Particulate by using well applied beta ray attenuation technology.

    Asian.webp
    CPCB.webp
    BHEL (2).webp
    CPGCL (2).webp
    CSIR.webp
    DRDO (2).webp
    Rajendra University.webp
    ECIL (2).webp
    HPGCL.webp
    Hindustan organic.webp
    ISRO.webp
    INS Jalaswa Logo.webp
    Dr.Reddy's (1).webp
    JINDAL STEEL.webp
    JSW (2).webp
    Madras Fertilizers.webp
    Meghamani Organics.webp
    Minister of Diffence.webp
    ONGC.webp
    Rastriya chemical Fertilzer.webp
    RFCL.webp
    Sigareni.webp
    RVUN.webp
    Tata.webp
    West Bengal.webp